Hot Tel:0086-577-86837881
English 中文

ENZYME HYDROLYSIS SYSTEM DEVICE

CONTACT US

Enzyme hydrolysis tank technology and its structural properties
1. volume:0.1M – 100m series specifications;
2.inner tank: mirror polishing inside surface, roughness Ra<0.4* m;
3.jacket type: fulljacket, half round coiljacket and honeycomb jacket.
4. insulation material: filled with pearl cotton, rock wool or polyurethane pouring foam;
5. shell surface treatment methods: mirror polishing or 2B primary color matte or sandblasting treatment;6. mixing speed: 12 150r/min fixed speed or equipped with stepless speed regulation and variable frequency speed regulation;
7. liquid level gauge: glass tube level gauge, static pressure sensor level gauge, ultrasonic liquid level meter, radio frequency capacitanceliquidlevel gauge;
8. equipment configuration: fast opening manhole, view mirror, thermometer (digital display or dial type), sampling port, ail respirator, CIP cleaner, material and liquid import and export, spare port, steam import and export, and cooling water import and export,etc.
9. material: inner tank SUS304 or US316L: acket and outer protection shell are SUS304:10. both the opening and the inner tank welding of the inlet and outlet, the view miror, the manhole and the inside can use the flanging process arc transition, which is smooth and easy to clean without dead angle, and the appearance is beautiful.